Purpose of Performance Evaluation Report (PER)
The Performance Evaluation Report (PER) stands as a key aspect of the overall IVDR technical documentation. The purpose of the performance evaluation is to produce the clinical evidence that supports the manufacturer’s intended use. Performance evaluation of a device is a continuous process by which data are assessed and analyzed to demonstrate the scientific validity, analytical performance, and clinical performance of that device for its intended purpose as stated by the manufacturer following a performance evaluation plan.
The performance evaluation shall be thorough and objective, considering both favorable and unfavorable data. Its depth and extent shall be proportionate and appropriate to the characteristics of the device including the risks, risk class, performance, and its intended purpose.
Introduction to In-Vitro Diagnostic Regulation (IVDR) Regulation (EU) 2017/746
The IVDR is the new regulatory basis for placing on the market, making available and putting into service in-vitro diagnostic medical devices on the European market. By repealing Directive 98/79/EC and Commission Decision 2010/227/EU, the updated Regulation (EU) 2017/746 dictates new requirements for generating Performance Evaluation Reports (PER). Performance evaluation is a must for any In Vitro Diagnostic Device (IVD) entering the European market. In the context of the EU, a regulation (IVDR) is similar to national law, and it will be effective in all (Europe Union) EU member states immediately without the need to be transferred into the law of respective states.
Some Important Updates
The IVDR promotes a shift from pre-approval to a life-cycle approach. In comparison to the list-based system under the IVDD, the IVDR provides for a risk-based classification system with classes from A to D.
The New General Safety and Performance Requirements:
The new General Safety and Performance Requirements (GSPR) replaced the Essential Requirements (ER). The GSPR is much more comprehensive than the former the Essential Requirements (ER) includes the following chapters:
IVDR Transition
During the transitional period, devices can continue to be certified and placed on the market according to the current Directives. This means that the Regulations will not be fully legally binding until 2021 and 2022, respectively. From 26 May 2022, all new certificates will have to be delivered according to the IVDR. Until May 2025, certain devices placed on the market under the Directives and certain devices placed on the market under the new Regulations will coexist on the market.
Here We Have Listed Some Key Elements / Steps to Create Exhaustive Performance Evaluation Report (PER)
Performance Evaluation Plan:
Clinical Evidence
Analytical Performance:
Clinical Performance:
Scientific Validity:
Performance Evaluation Report:
Clinical Performance Study Report
A clinical performance study report, signed by a medical practitioner or any other authorized person responsible, shall contain documented information on the clinical performance study protocol plan, results, and conclusions of the clinical performance study, including negative findings. The results and conclusions shall be transparent, free of bias, and clinically relevant. The report shall contain sufficient information to enable it to be understood by an independent party without reference to other documents. The report shall also include as appropriate any protocol amendments or deviations, and data exclusions with the appropriate rationale.
Conclusion
IVDR technical requirements are significantly shifting the IVD industry, and these changes require a more thorough approach to IVD development that ensures that claims are accurate, and devices are safe. Demonstrating device performance through Technical Documentation must be satisfied, with Clinical Performance, Scientific Validity, and Analytical performance playing key roles. It should also be noted that Technical Documentation does not end with a Sponsor’s submission but should constantly be updated as it evolves throughout the device lifecycle.
Learn more visit our white paper Insights | White Papers
SARACA is a rapidly growing product engineering services company with deep expertise in digital, artificial intelligence, and emerging new technologies. Founded in 2014, SARACA is powered by Gen Z and Millennials with greater focus on agility, customer centricity, faster technology adoption, and adherence to cultural sensitivity. Our digital natives perform their actions with speed and ensure that we exceed customer expectation every single time. SARACA adopted vertically integrated approach to build depth in the industries we operate in. Over the years we have built strong expertise in aerospace, defense, space, automotive, medical devices, Industrial, Farm Equipment, rail transportation, technology, semiconductor, and many other industries.